SERVICE UNIT

3.3 SERVICE UNIT
    The service unit is nothing but the built in package of combination of filter, pressure regulator and lubricator.

AIR FILTER
    The purpose of air filter is to clean the compressed air of all impurities and any condensation that might be entered with the intake air and delivered by the compressor.

PRESSURE REGULATOR
    The pressure regulator are reducing valve assigned the duty of maintaining a largely constant operating regulator of  fluctuations in the air main pressure and air consumption rate. The inlet pressure must always higher than the outlet pressure.

LUBRICATOR
    The lubricator is required to ensure an adequate supply of lubricant to the pneumatic equipment. The lubrication is done by injecting the oil into the air stream. The lubricator start working only when the airflow reaches a certain rate, below which the velocity across the nozzle is to low to draw oil into the air stream. Only thin mineral oil may be used in pneumatic system lubricator. Viscosity ratings are normally 2 to 5 degree Engler at 20 degree Celsius or 10 - 50 centistrokes. The rule to be observed for complete service unit is that the flow and pressure range specified by the manufactures must be maintained or the unit must be selected to suit the given parameter of flow and pressure.

Model FRLM 13.
Medium Compressed Air
Port size G 1/4
Pressure gauge Port size G 1/8
Floe rate its/min @ 500
Max Supply Pressure 10 Bar
Regulating Pressure Range 0.5 -  10 Bar
Medium Temperature 5 - 60 degree Celsius
Filtration 50 micro m
Min Operating Flow its/min 12
Bowl Capacity Filter 9 ml
Bowl Capacity Lubricator 20 ml
Recommended Oil ISO VG 32 ( Servo system 32 )
Bowl Material PolyCarbonate
Installation Any Position for Regulator. Vertical for Filter and Lubricator
Materials of construction Aluminum, Bronze, Brass, Steel, Acetal
Weight 0.72 kg
Optional Accessories Pressure Gauge

@ - SUPPLY PRESSURE 7 BARS, SET PRESSURE 6 BARS
PRESSURE DROP  ΔP = 1 BAR ( STANDARD MODEL ).